Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
CLAN-BD (Control LAN Circuit Pack)
Issue 1 June 2005 797
s. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that reported
threshold number of errors. One or more of the following symptoms may be present:
Circuit pack port tests return NO BOARD.
List configuration command shows circuit pack and ports are installed properly
1. Busyout (busyout board location) and release (release board location)
circuit pack
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (busyout board
location), reset with reset board location, and release (release board
location) the circuit pack.
4. If error recurs within 15 minutes, replace the circuit pack.
5. If the same error occurs on a different circuit pack, follow normal escalation procedures.
t. Error Type 3840: Circuit pack received bad control channel message from switch.
Aux Data:
If Error Type
3999:
And
traffic
volume
is:
Then:
Does not
accompany Error
Type 3586,
Heavy Circuit pack is in service, but sent at least half hyperactive
threshold. With heavy traffic, this is normal.
Does not
accompany Error
Type 3586,
Light Circuit pack is in service, but sent at least half hyperactive
threshold. With light traffic, this error indicates a problem
with the circuit pack, its links, or the equipment attached to
the links.
Accompanies
Error Type 3586,
Light or
Heavy
Switch removed hyperactive circuit pack.
4096 Bad major heading
4097 Bad port number
4098 Bad data
4099 Bad sub-qualifier
4100 State inconsistency
4101 Bad logical link
4102 Bad application identifier