CO-TRK (Analog CO Trunk)
Issue 1 June 2005 847
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the service state indicates that the port is active, then it is
unavailable for certain tests. Wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1004 ABRT The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the service state indicates that the port is active, then it is
unavailable for certain tests. Wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1005 ABRT Test inapplicable to present configuration. This is a normal condition.
1018 ABRT Test has been disabled by administration.
1. For this test to run, the Maintenance Tests field on the Trunk Group
form must be n. Use change trunk-group <grp> to check the
field.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
Table 289: Test #3 CO Demand Diagnostic Test (continued)
Error
Code
Test
Result
Description / Recommendation