Communication Manager Maintenance-Object Repair Procedures
724 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2069 ABRT The endpoint has returned an error response to the application message
sent by the switch.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2000 FAIL No loop back activation or deactivation response is received from the
endpoint.
1. Consult the endpoint documentation to determine if ISDN-BRI
Management and Maintenance Procedures are supported. If not
supported, use change station extension to set the MIMs
Supported field to n. Use busyout station extension and
release station extension to busyout and release the endpoint
to resolve any endpoint alarms resulting from failure of this test.
2. If the endpoint supports these procedures and the test continues to fail,
assume the endpoint is defective and replace it.
2071 FAIL No data is detected on Channel B1 during loop back.
2072 FAIL No data is detected on Channel B2 during loop back.
1. Replace the endpoint and repeat test.
2. If test continues to fail, check the wiring between the endpoint and the
switch and repeat the test.
PASS The endpoint has responded to the switch activate and deactivate loop back
application messages. Data has been detected on the looped back
channels.
Table 244: Test #627 BRI Remote Loop Back (continued)
Error
Code
Test
Result
Description / Recommendation