ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005 641
1033 ABRT ATM-TRK circuit pack not found
1. See if the switch can see the circuit pack. Run status
trunk-group.
2. Retry the command.
1139 ABRT Major alarm on the PN’s packet bus
1. Run display alarms, and perform the repairs associated with
PKT-BUS errors.
2. Run display errors, and perform the repairs associated with
PKT-BUS errors.
3. Retry the command.
1141 ABRT Packet-interface circuit pack out of service
1. See PKT-INT (Packet Interface)
.
1394 ABRT ATM-TRK circuit pack out of service
1. Run ATM Board Reset Test #1256.
2000 ABRT Request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2060 ABRT Packet-bus link has failed.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to abort, run display errors, and perform the
repairs associated with PKT-INT errors.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
Table 218: ATM Board Framer Loop-Around Test (#1260) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4