DIG-LINE (Digital Line)
Issue 1 June 2005 943
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Enter display port location to determine the station extension
or attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in
use, wait until it is idle before testing. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Electronic Power Feed test passed. The message to turn on the power to
the station was successfully sent to the port.
1. Although, except for the previous Internal system error, this test never
actually returns a FAIL result, it will log an error indicating the real
results of the test. Check the Error Log for any entries with Error Types
767 or 769 after the test completes.
2. If Error Type 767 appears in the Error Log, this indicates that the test
sensed no problems with the power to the station. To verify that the
station is powered up correctly, run a self-test on the station and check
that every feature button is operating.
3. If Error Type 769 appears in the Error Log, this indicates some
problem with the power to the station. Check for a short in the wiring, a
damaged jack, a defective voice terminal, or an incorrect type of
terminal.