Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 June 2005 367
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, it is unavailable for certain tests. Wait until the port is idle
before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT This condition indicates that the test is not applicable when the analog port is
used in a combined modem pool. This error can be ignored.
1018 ABRT Test disabled via administration.
1. To enable the test for the particular analog station being tested, enter
change station extension.
2. Enter y in the Test field.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2012 ABRT System could not respond to this request.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests, by examining
station wiring, or by examining the station.
Table 100: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2