Communication Manager Maintenance-Object Repair Procedures
1440 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1113 ABRT The signaling channel is down. Therefore, no messages can be sent to the
far-end switch or terminal adapter.
1. Examine the results of Tests #636 and #639 and follow
recommendations provided there.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
or
none
ABRT Internal system error or administration problem
1. Determine whether any B channels are administered. If not, then this is
a normal ABORT, since this test cannot run unless at least one B
channel is administered. If at least one B channel is administered, there
is an internal system error. Retry the command at 1-minute intervals up
to 5 times.
FAIL Internal system error. See description of ABORT with error code 2500.
PASS A message was composed and sent to the far-end switch or terminal
adapter. The ISDN PRI specification allows up to 2 minutes for a reply.
1. Check the Error Log for ISDN-SGR (ISDN-PRI Signaling Group)
on
page 1429 for errors of type 2305 for evidence of a Remote Layer 3
Query failure. If no new errors were logged since this test was run, then
this switch and the far-end switch or terminal adapter can exchange call
control messages.
2. If there is still a problem with a particular ISDN trunk or PRI endpoint,
busyout the trunk and run the long test sequence, paying particular
attention to the results of Test #258 (ISDN Test Call).
Table 517: Test #637 Remote Layer 3 Query (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3