Session Status Test (#1286)
This nondestructive test determines the status of every PPP port session. This test queries the
system software on port session status.
If the system software indicates that: Then the switch:
Every port session is up (ALL UP) Raises no alarm, or retires alarm
Some port sessions are up (SOME UP) Raises MINOR alarm
Every port sessions is down (ALL DOWN) Raises MINOR alarm
Table 695: Test #1286 Session Status Test
Error
Code
Test
Result
Description / Recommendation
1124 ABRT PPP link is not enabled.
1. Verify that the ppp link is enabled (status port location,
status link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
1125 ABRT PPP link not in service.
1. Verify whether PPP link is in service (status port location or
status link n).
2. If the PPP link is not in service, release the link (release link n
or release port location).
3. Repeat the test.
2000 ABRT Did not receive circuit pack test response within the allowable time
period.
1. If the problem persists, reset the circuit pack (busyout port
location, reset board location, and release board
location).
2. If the problem persists, replace the circuit pack.
2100 ABRT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.