1113 ABRT The signaling link between the switch and the endpoint or adjunct is down.
1. Use test port location long to clear any errors that prevent
establishment of the signaling link.
2. Examine the results of Test #626 that are executed with the command.
If this test aborts or fails, follow the repair procedure for the Signaling
Link Status test.
3. Escalate problem if BRI Layer 3 Query test continues to abort.
1139 ABRT The PN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute test port location long, and
review the results of the BRI Port Local LAN Loop Around test (#618)
to verify the repair.
1141 ABRT The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL (Packet Control Circuit
Pack) Maintenance documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
Table 246: Test #629 BRI Layer 3 Query (continued)
Error
Code
Test
Result
Description / Recommendation