Communication Manager Maintenance-Object Repair Procedures
1746 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT The test was aborted because system resources required to run this
test were not available. The port may be busy with a valid call.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. You must wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5
times.
1006 ABRT The test was aborted because the station is out of service. This
condition may be accompanied by an error type 18 entry in the error
log. You may want to determine why the station was taken out of
service. (When stations are taken out of service by maintenance
software, the problems that preceded that point must be cleared.)
1. Use status station to check the service state of the port. If the
port is indeed out of service, enter release station to bring the
station back into service.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test aborts with Error Code 2000 again, run short test
sequence on the associated DS1-BD or UDS1-BD. If tests 138
through 145 on the associated DS1-BD or UDS1-BD are also
aborting with Error Code 2000, hyperactivity on the board or facility
is indicated. In this case, the hyperactivity problem should be dealt
with first.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 or 8 FAIL Test failed due to internal system error. Do not replace port board.
Error code 7: the failure occurred during station translation download (to
DS1 Interface circuit pack).
Error code 8: the failure occurred during station ringer update.
1. Retry the command at 1-minute intervals up to 5 times.
Table 646: Test #36 Audit and Update Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3