Communication Manager Maintenance-Object Repair Procedures
356 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow the recommended procedures
Table 96: EMBEDDED AUDIX Digital Port Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/
Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test port location sh r 1
1 (b
) 40987 None WRN OFF
1 (c
) 1 to 20 None WRN OFF
15 (d
) Any None
18 (e
)0 busyout port
location
WRN OFF release port location
23 (f
) 0 None WRN OFF
130 (g
) None WRN ON test port location sh
257 (h
) 40971 None
513 (i
) Any None
1537 (j
) 40968 None WRN OFF
1793 Voice and Control
Local Loop Test
(#13)
MIN
WRN
1
1. Minor alarms may be downgraded to Warning alarms based on the values used in set options.
ON test port location l r 3
2049 NPE Crosstalk
test (#9)
MIN
WRN1
ON test port location l r 3
2305
(k)
40967 None
3840 (l
) 40965 None
3840
(m
)
41029 None