Communication Manager Maintenance-Object Repair Procedures
1530 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
NPE Connection Audit Test (#50)
The system sends the circuit pack’s on-board microprocessor a message to update the
network-connectivity translation for its SCOTCH-NPE chip.
Red Alarm Inquiry test (#140) N X X ND
Yellow Alarm Inquiry test (#141) N X X ND
Major Alarm Inquiry test (#142) N X X ND
Minor Alarm Inquiry test (#143) N X X ND
Slip Alarm Inquiry test (#144) N X X ND
Misframe Alarm Inquiry test (#145) N X X ND
Translation Update test (#146) N X X ND
SAKI Sanity test (#53) Y X D
1. N = No; this test either passes or ABORTS with Error Code 2000 (problem with NT)
2. D = Destructive; ND = Nondestructive
Order of Investigation Apply to
TN802?
1
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
D/ND
2
2 of 2
Table 552: Test #50 NPE Connection Audit Test
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1019 ABRT The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The circuit pack’s SCOTCH-NPE chip has been updated with its
translation.
1 of 2