MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005 1637
1 to 17
(
cont’d)
FAIL If the MM710 connects to a line-side terminating device such as a PRI
terminal adapter:
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. Enter list measurement ds1-log GGGVS to read the error
seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are
administered using the same signaling mode, framing mode, and
line coding.
4. Investigate the maintenance status of the line-side terminating
device. Refer to the 'Line-Side Terminating Device Operating
Manual' for information.
5. Check the physical connection of the MM710 interface Media
Module to the terminating device, and check the premise
distribution system (or the intra-premise wiring) for physical
connection failures.
6. Replace the local MM710 interface Media Module and repeat the
test.
7. Contact the vendor of the line-side terminating device to diagnose
the equipment.
PASS No Misframe alarm is detected on the MM710 Interface Media Module.
Table 599: TEST #145 Misframe Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description/ Recommendation
3 of 4