Communication Manager Maintenance-Object Repair Procedures
688 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: the Level 1 Status Inquiry fails or when the BRI circuit pack detects that Level
1 has been deactivated on the port. Refer to the repair procedures for Test #621.
Aux Data blank: the Level 1 Status Inquiry failed.
Aux Data 32773: message from the BRI-LINE circuit pack indicating Level 1 has been
deactivated.
130(c)WRNONtest port PCSS sh
257(d
EPF Inquiry (#622) WRN MAJ
MIN
WRN2
OFF test port PCSSpp sh r 1
513(e
) 46222 none (d) (d) ON
769(f
) 0 none WRN MAJ OFF
1281(g
) NPE Crosstalk (#617) MIN
WRN2
ON test port PCSSpp l r 2
1537(h
) 46210 CRC Error Counter
(#623)
WRN MAJ
MIN
WRN2
OFF
1793(i
) BRI Port Local TDM
Loop Around (#619)
MIN
WRN2
ON test port PCSSpp l r 2
3841(j
46208 None
3842(k
)0 None
3843(l
)0 None
3844(m
) 46223 None
3845(n
)None
3846(o
)TEI None
3847(p
)0 None
1. Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value used in set
options.
Table 230: ISDN-BRI Port Error Log Entries (continued)
Error
Type
Aux
Data
Associated
Test
Alarm
Level
BRI-
PORT
Alarm
Level
ABRI-PORT
ATT-PORT
LGATE-PT
ATTE-PT
On/Off
Board
Test to Clear Value
2 of 2