DIG-LINE (Digital Line)
Issue 1 June 2005 947
1 ABRT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port via release station
extension and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3 ABRT Station may be in ready-for-service or out-of-service state.
1. Use status station to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension or
attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in
use, wait until it is idle before testing. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1392 ABRT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either display port (the port
is a TTI port) or list config (a “t” shows for the port).
2. If either list config or display port indicates that the port is not
a TTI port, escalate the problem. If both commands indicate that the
port is a TTI port, the abort is correct, and no action is necessary.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Table 324: Test #16 DIG-LINE Station Lamp Updates Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3