TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005 2295
s. Error Type 3590: an activated BRI port receives a frame containing a DLCI over a
D-Channel for which it does not have a translation. This error normally indicates an
off-board problem related to a state mismatch between the far-end and the switch. This
error is logged only.
t. Error Type 3591: the circuit pack received a frame containing a DLCI over the TED
D-channel for which it does not have a translation. This error occurs only on a system that
switches the packet implementation of the D-channel over the TDM bus and indicates an
off-board problem related to the state mismatch between the board and the packet
implementation of the TDM D-channel. This error is logged only.
u. Error Type 3592: the port is generating too many uplinks and is taken out of service.
v. Error Types 3841-3942: Table 821: Aux Data Error Types 3841-3942
on page 2295
contains the received ISDN cause values for Error Types 3841-3942 that are recorded in
the hardware error logs. Unless otherwise stated, the cause values are D-Channel events.
The Aux Data field shows which port caused the error.
Table 821: Aux Data Error Types 3841-3942
Value Type of Problem Meaning
2 admin No route to specific transit network
3 admin No route to destination (or Germany bcap not imp)
6 admin Channel unacceptable
18 switch problems No user responding
38 switch problems Network failure
50 subscription Requested facility not subscribed
52 admin Outgoing calls barred
54 admin Incoming calls barred
62 subscription Service not authorized
63 admin/sub Service/option not available
65 admin/sub Bearer capability not implemented
66 admin/sub Channel type not implemented
69 admin/sub Requested facility not implemented
70 admin/sub Only restricted digital BC available
79 admin Service/option not implemented
88 admin Incompatible destination
102 switch problems Recovery on timer expired