SYS-PRNT (System Printer)
Issue 1 June 2005 2183
See Procedures for Restoring the System Printer Link on page 2181 for recommended
maintenance strategy.
c. Error Type 513: the SYS-PRNT was interrupted for one of the following reasons:
● The cable to the SYS-PRNT output device is disconnected
● The SYS-PRNT output device is powered off
● The data extension to which the SYS-PRNT output device connects has been busied out
● Internal software error
Check the connectivity of the wires and cables among the wall jacket, data module, and
SYS-PRNT output device. Follow the instructions in Procedures for Restoring the System
Printer Link on page 2181.
System-Technician-Demanded Tests: Descriptions And Error
Codes
Investigate tests in the order presented below. Clearing error codes associated with the one test
may also clear errors generated from other tests in the sequence.
Table 777: Aux Data, Error Type 257
Aux
Data
Description
1 No C-LAN port available. See CLAN-BD (Control LAN Circuit Pack)
on
page 789 for explanation.
3, 4 Time-out during setup attempt. Most likely due to problem with physical link
or printer status.
5 Internal system error. Most likely temporary/sporadic failure.
2, 6 The data module the printer is trying to use is busy with another call. Use
status data module to determine when the port is available for testing.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
Link Tear Down test (#213) X D
Link Retry test (#215) X X ND