Communication Manager Maintenance-Object Repair Procedures
794 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
g. Error Type 1293-1297: Critical hardware or firmware error.
Error Type descriptions are as follows:
1. Attempt to clear the alarm with reset board location.
2. If alarm persists, replace circuit pack.
h. Error Type 1537: Switch removed hyperactive circuit pack that reported threshold number
of errors.
1. Attempt to clear the alarm with reset board location.
2. If the error recurs within 15 minutes, replace the circuit pack.
i. Error Type 1794: Packet-bus transmit buffers have overflowed.
1. Attempt to clear the alarm with reset board location.
2. If the error recurs within 15 minutes, replace the circuit pack.
j. Error Type 1796, Aux Data 42611: DLCI out of range. The switch activates congestion
controls on CLAN when it detects buffers exceeding the threshold. The switch releases the
congestion controls when the CLAN reports that its buffer level has returned to normal. A
minor alarm is raised if congestion persists for 14 minutes or if buffers are exhausted
because of congestion. The alarm is retired when the alarm condition ceases for 12
minutes.
1. Attempt to clear the alarm with reset board location.
2. If the alarm recurs within 15 minutes, replace the circuit pack.
Aux Data Any: Bad DLCI.
If the switch detects: Then the switch:
1 error, Resets circuit pack.
3 errors in 15 minutes, Raises MINOR alarm.
1293 Insane onboard processor
1294 Onboard translation RAM error
1295 (Aux 3) RSCL link down
Software requested a reset of the CLAN because it failed to get a keep-alive
response from the CLAN for over a minute.
(Aux 0) RSCL keep alive failure
1296 Software requested a reset of the CLAN.
1297 Software requested a reset of the CLAN