Table 233: Test #619 BRI Port Local TDM Loop Around
Error
Code
Test
Result
Description / Recommendation
1000 ABRT The system resources required to run this test are not available. The port
may be busy with a valid call.
1. Use display port location to determine the station extension or
trunk group/member number of the port. Use status bri-port
location to determine the service state of the port. If the service
state indicates that the port is active, then the port is unavailable for
certain tests. (Refer to Maintenance SAT Commands
in Maintenance
Commands Reference (03-300191) for a full description of every
possible state.) Wait until the port is idle before retesting.
2. If the port is idle, then retry the command at 1-minute intervals up to 5
times.
3. If the test continues to abort, escalate the problem.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
4. If the test continues to abort, escalate the problem.
1004 ABRT The port has been seized by a user for a valid call. Use status station
for the station associated with this port and determine when the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
1 of 2