MET-LINE (MET Line)
Issue 1 June 2005 1575
MET Line Station Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status record contained
in the processor. The lamp updates run only if the station is in-service.
Table 582: Test #60 MET Line Station Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port using release
station extension and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
3 ABRT Station is in ready-for-service or out-of-service state. This may be due to
wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension of
the port. Use status station to determine the service state of the
port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS MET Line Station Lamp Updates completed successfully.
1. If complaints persist, investigate by using other circuit pack tests, and
by examining the station, wiring, and connections.