TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005 2325
FAIL Measured transmission performance was in the unacceptable range as
administered on the trunk group screen. Retrieve a measurement report
using list testcalls. Make sure that ATMS thresholds are set properly
on page 4 of the trunk group screen. Besides the facility, test failures can be
caused by faulty test lines or switch paths. If the measurements point to a
facility problem, report the results to the trunk vendor.
FAIL Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report using
the list testcalls command. Make sure that ATMS thresholds are set
properly on page 4 of the Trunk Group form. Besides the facility, test failures
can be caused by faulty test lines or switch paths. If the measurements point
to a facility problem, report the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the marginal range as
administered on the trunk group screen. This generally means that the trunk
is usable but has an undesirable amount of noise or loss. If the user does
not report unacceptable effects, it may not be necessary to take any action.
Retrieve a measurement report using list testcalls. Make sure that
ATMS thresholds are set properly on page 4 of the Trunk Group screen.
Table 834: Test #844-848 Transmission Test (continued)
Error
Code
Test
Result
Description / Recommendation