Communication Manager Maintenance-Object Repair Procedures
2272 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
257 (g) 57473
57474
513 (h
) 57392 DS1 Tie Trunk
Seizure (#136)
MAJ
MIN
2
769 (i) 57393 DS1 Tie Trunk
Seizure (#136)
MAJ
MIN
2
1025 DS1 Tie Trunk
Seizure (#136)
MIN
WRN
2
OFF test trunk grp#/mem# r 2
1281 Conference Circuit
Test (#7)
MIN
WRN
2
ON test trunk grp#/mem# l r 4
1
1537 NPE Crosstalk Test
(#6)
MIN
WRN
2
ON test trunk grp#/mem# l r 3
1
1793 (j) test board location long
1
2305 (k) 50944 DS1 Tie Trunk
Seizure (#136)
MAJ
MIN
2
OFF
2562 (l
) 16665
2817 (m
) 52992
3840 (n
) Any Port Audit and
Update (#36)
1. For TN767B vintage 8 or 9 circuit packs, a failure of Test #136 causes a subsequent failure of
Test #7. Test #136 is part of the short sequence and generates off-board alarms. Test #7 is part
of the long sequence and generates on-board alarms. Before entering busyout, release, reset or
test board long commands, check the vintage number of the circuit pack with
list
configuration board location
. If it is TN767B vintage 8 or 9, do not use the above
commands until you ensure sure that Test #136 passes via test board short. Otherwise,
extraneous on-board alarms may be generated.
2. *Major or Minor alarms on this MO may have been downgraded to Warning based on the values
in
set options.
Table 814: DS1 Tie Trunk Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2