Communication Manager Maintenance-Object Repair Procedures
850 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the port is active, wait until it is idle before testing.
2. If the port status is active but the port is idle (no calls), check the error
log for error type 1025 (see the error log table for a description of this
error and required actions). The port may be locked up. Check the CO
wiring, check for excessive loop current, and check the trunk
translations. (If the trunk is translated incorrectly, this test will abort.)
3. If the port status is idle, busyout and release the trunk, and retry the
command at 1-minute intervals up to 5 times.
4. If the test still aborts, replace the circuit pack.
1001 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to
5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the port is active, wait until it is idle before testing.
Table 290: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3