Server Alarms
96 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Alarm Log Entries
Notes:
1. Event ID #1 Handshake Test failed — With 3 consecutive failures of either the periodic or
on-demand test, the following Minor alarm is logged:
#1,ACT,USB1,A,1,MIN,USB Modem handshake test failed
2. Event ID #2 Modem Off-Hook test failed — With 3 consecutive failures of this test, the
following Major alarm is logged:
#1,ACT,USB1,A,2,MAJ,USB Modem Off-Hook test failed
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following table. For example, by clearing
error codes associated with the Handshake test, you may also clear errors generated by other
tests in the testing sequence.
-t arg Specific test to perform.
Possible values for arg are: reset_usb | handshake | off-hook |
-? Usage (this).
Table 27: USB1 Alarm Log Entries
EVENT
ID#
Aux
Data
Associated Test Alarm
Level
On/
Off
Board
Linux Test to
Clear Value
1 (1
) Handshake test MIN ON testdupboard
2 (2
) Modem Off-Hook test MAJ ON testdupboard
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Handshake test X X D
Off-Hook test X X D
Reset USB test X X D