DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005 957
1001 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Use status health to determine if the system is
experiencing heavy traffic.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Enter list measurements tone-receiver to see information
about the system’s tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004 ABRT The port has been seized by a user for a valid call. Use status trunk to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020 ABRT The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
Table 328: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3