FAIL The terminal equipment is not connected to the circuit pack or the ringing
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, see RING-GEN (Analog Ring Generator)
on page 1942
(analog ring generator) maintenance.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the set may be defective. Check the set, and
replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is
connected properly. If this is the case, disable the test using change
station extension (enter n into the Test field). Note that this
action also disables Tests 6, 7, 161, and 35 on this port.
PASS The station is connected properly to the switch. This test may also pass if
no terminal equipment is connected and the terminal is located very far from
the switch. Investigate user-reported troubles on this port by using other
port tests or by examining the station and its wiring.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Enter list config
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If
not, dispatch to verify that a valid board is inserted.