FIBER-LK (Fiber Link)
Issue 1 June 2005 1285
236 FAIL The Endpoint 2 SNI’s administered neighbor does not match the physical
neighbor connected. Use list fiber-link to see a fiber link’s
endpoints. The SNI’s assigned neighbor is another SNI, but the SNI is
physically connected to an EI. Enter list fiber-link and verify that the
fiber-optic and metallic cables are installed as administered.
237 FAIL The Endpoint 2 SNI’s administered neighbor does not match the physical
neighbor connected. Use list fiber-link to see fiber link endpoints.
The SNI’s assigned neighbor is an EI, but the SNI is physically connected to
another SNI. Enter list fiber-link and verify that the fiber-optic and
metallic cables are installed as administered.
238 FAIL The physical location of SNI Endpoint 2’s neighbor does not match its
administered location. Use list fiber-link to see a fiber link’s
endpoints. One location (carrier and slot) is assigned for the endpoint’s
neighbor, but it physically resides in another location.
1. Enter list fiber-link and verify that the fiber-optic and metallic
cables are installed as administered.
2. If the problem does not seem to be caused by either a
physical-connection or an administration problem, replace the
neighbor circuit pack. The neighbor circuit pack may have a hardware
problem causing it to report a wrong angel address (physical carrier/
slot address) to software.
239 FAIL The SNI Endpoint 2 is assigned to be connected to a DS1 converter, but is
not physically connected to one. Use list fiber-link to see a fiber
link’s endpoints.
If this SNI endpoint should be connected to a DS1 converter:
1. Enter list fiber-link to verify that the fiber-optic cable and/or
metallic cable connections are installed as assigned.
If not, change administration to remove the DS1 converter complex from
the SNI’s fiber link:
1. Enter list fiber-link to locate this SNI endpoint’s fiber
2. Enter remove fiber-link for this SNI endpoint’s fiber
3. Enter add fiber-link to replace the fiber without assigning the
DS1 converter complex.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation