Communication Manager Maintenance-Object Repair Procedures
1550 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
NIC Query Test (#1383)
This test is nondestructive.
The test passes if the Ethernet port is connected, and you can talk on the network. Otherwise, it
fails with no fail code or AUX data.
Table 570: Test #1383 NIC Query Test
Error
Code
Test
Result
Description / Recommendation
None ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1015 ABRT Port is not out-of-service.
1. Busyout the circuit pack (busyout board location).
2. Execute the command again.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The Ethernet port is not connected, and you cannot talk on the network.
PASS The Ethernet port is connected, and you can talk on the network.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the
MedPro interface if it is not already administered.
2. If the board was already administered correctly, check the error log
to determine whether the board is hyperactive. If so, the board was
shut down. Reseating the board re-initializes it.
3. If the board was found to be inserted correctly, enter busyout
board location.
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.