Communication Manager Maintenance-Object Repair Procedures
992 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
SAKI Sanity Test (#53)
This test is destructive. This test resets the circuit pack.
Table 342: Test #53 SAKI Sanity Test
Error
Code
Test
Result
Description / Recommendation
None ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABRT Wrong circuit pack configuration to run this test. This error applies only to
DS1 Interface circuit packs. It means the DS1 Interface circuit pack is
providing timing for the system and, therefore, it cannot be reset without
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to
another DS1 Interface circuit pack or to the Tone-Clock circuit and try
again. Refer to “SYNC (Synchronization)”.
1015 ABRT Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute the command again.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute the command again.
2. If the problem persists, escalate this problem.
PASS The circuit pack initializes correctly.
1. Run the short test sequence.
1 of 2