Communication Manager Maintenance-Object Repair Procedures
1558 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2801 ABRT The TN802B/TN2302 Media Processor board has not been administered
on the ip-interfaces screen.
ANY FAIL The test did not detect the test tone through the looparound connection.
1. Test the tone-clock in the port network that contains the media
processor under test.
2. If the tone-clock is healthy, test the media processor board again.
3. If the test continues to fail, replace the media processor board.
PASS The board is functioning properly.
0NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131)
issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error 1538). If hyperactive, use reset board
location.
3. Run the test again. If it fails, the NCE chip on board may be bad.
Replace the board and retest.
Table 574: DSP PORT TDM Loop-Around Test (#1380) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2