Communication Manager Maintenance-Object Repair Procedures
546 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Verify that at least one Tone Detector resides in this PN. (Even
without a TTR-LEV error, the tested circuit pack’s PN could be missing
a Tone Detector.)
If missing, the test always aborts for this circuit pack, without harming
the system.
Note:
Note: A TN2182 Tone-Clock circuit pack in a PN must be of
vintage B or newer. If an earlier vintage resides in a PN,
this test always aborts with this abort code.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
Table 174: Expansion Interface 2-Way Transmission Test (#241) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 8