Communication Manager Maintenance-Object Repair Procedures
2470 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
The list measurements ds1 summary command will display the length of time the test ran
(Test Duration field) and number of bit errors detected (Loopback/Span Test Bit-Error Count
field).
To restore the trunks or ports on the UDS1 Interface circuit pack to the in-service state, execute
release board location.
Table 874: Test #1216 End Loopback/Span Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry test ds1-loop location end-loopback/span-test at
1-minute intervals up to 5 times.
1005 ABRT End Loopback/Span test cannot be executed in the current configuration.
To run this test, the TN464F or higher suffix DS1 board must be
administered for 24-channel operation. The Bit Rate field on the DS1
circuit pack administration screen must be set to 1.544 for 24-channel
operation.
1015 ABRT Ports on the UDS1 Interface circuit pack have not been busied out.
1. Enter busyout board location to put each trunk or port of the
UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1 of 3