M/T-ANL (Maintenance/Test Analog Port)
Issue 1 June 2005 1699
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors. A system is considered under heavy traffic when the Call
Processing Occupancy is greater than 50% or when the System
Management and the Call Processing Occupancies together exceed 65%.
To view the system occupancy measurements enter status health on
the system technician terminal.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 3 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 3
times.
1004 ABRT The port has been seized by a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test
call, escalate the problem. To determine whether the port is in use by
an ATMS test call, enter status station ext where ext is the
assigned ATMS station’s number.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
Table 627: Test #9 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3