ANL-LINE (8-Port Analog Line)
Issue 1 June 2005 405
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
Table 119: 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/
Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test port location sh r 1
1 (b
) 40960
40975
40977
None
15 (c
) Any Audits and Updates
(#36)
18 0 busyout station
extension
WRN OFF release station extension
130
(d
)
None WRN ON test port location sh
257
(e
)
Station Present test
(#48)
WRN OFF test port location sh r 3
513 Battery Feed test (#35) MIN
WRN
1
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON test port location sh r 2
769 (f
) Loop Around &
Conference (47)
test port location l r 3
1025 NPE Crosstalk test (#6) MIN
WRN
1
ON test port location l r 3
1281
(g
)
1793
(g
)