Communication Manager Maintenance-Object Repair Procedures
382 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT The test was aborted because system resources required to run this test
were not available. The port may be busy with a valid call. Use display
port PCSSpp to determine the station extension of the port. Use status
station to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting.
1. If the port is idle, retry the command at 1-minute intervals a maximum
of 5 times.
1004 ABRT The port received an EXT-DEV failure during the test. The test has been
aborted.
1. Before retesting, enter test external-device-alarm port
location to determine whether the port is reporting an EXT-DEV
failure.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
1006 ABRT This port has been busied out by command.
1. Check Error Log for Error Type 18 (port busied out). If present, use
release port location to release the port and run the test again.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 FAIL This failure does not indicate a hardware problem. The switchhook audit
failed. This condition may occur when the audit is performed at the same
time that the terminal equipment goes off-hook.
1. Before retesting, enter test external-device-alarm port
location to determine whether the port is reporting an EXT-DEV
failure. Wait until the port has no EXT-DEV failures.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
7 FAIL The translation update failed. This does not indicate a hardware problem
but may be an internal software error.
Table 111: Test #36 Station Status and Translation Audits and Updates (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3