ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005 633
The test passes if the port circuit pack responds. The test aborts if the circuit pack does not
respond. The test fails otherwise.
Table 212: Control Channel Test #52
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Test request timed out.
2100 ABRT Could not allocate needed system resources.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
FAIL The ATM circuit pack responded incorrectly.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to fail, reset the ATM-TRK circuit pack with reset
board location.
3. If test continues to fail, replace the circuit pack or transceiver.
PASS The ATM-TRK circuit pack is communicating correctly with the software.
0
NO
BOARD
Circuit pack not detected.
1. Check the error log for Error 125 (wrong board) or Error 131 (no
board), and correct any errors found.
2. Make sure that the ATM-TRK circuit pack is properly translated and
inserted.
3. Check for Error 1538 (hyperactivity). If hyperactive, run reset board
location.
4. Run the test again. If it fails, replace the ATM-TRK circuit pack, and
retest.