UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005 2401
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be initiated with
reset board location.
PASS Communication with this circuit pack is successful.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute add ds1
location to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log
to determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter
busyout board location
4. Enter reset board location
5. Enter release board location
6. Enter test board location long
This should re-establish the linkage between the internal ID and the port.
Table 855: Test #52 Control Channel Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2
Table 856: Test #53 SAKI Sanity Test
Error
Code
Test
Result
Description / Recommendation
None ABRT System resources required for this test are not available.
1. Retry reset board location at 1-minute intervals up to 5 times.
1 of 3