Communication Manager Maintenance-Object Repair Procedures
760 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
CMC1
Notes:
a. Error Type 0: Run the Short Test Sequence first. If all tests pass, run the Long Test
Sequence. Refer to the appropriate test description and follow the recommended
procedures.
b. Error Type 1: the Power/Fan Status lead indicates that the power supply of one or more
CMC1 cabinets has detected an alarm condition. The condition can be caused by the failure
of any fan or the failure of any power supply output. If more than one CMC1 cabinet exists,
all of the Power/Fan Status leads are tied together (the fan and power lead is an O-ring of all
cabinets’ status leads). Since an error condition on a fan or power supply output could be
the result of a temporary overload (e.g. during board insertion) or caused by the location of
the equipment (e.g. fan blockage), a single event may be an anomaly that eventually clears.
However, a repeating condition will cause a major alarm.
c. Error Type 257: temperature Sensor 1: Since temperature alarms can be transient, a single
event may be an anomaly that eventually clears. However, a repeating condition will cause
a major alarm and may indicate a need to replace one or more components (e.g. a Cabinet
Fan may be bad, or check to see if the equipment room air conditioning supply/unit is
functional).
d. Error Type 513: temperature Sensor 2: Since temperature alarms can be transient a single
event may be an anomaly that eventually clears. However, a repeating condition will cause
a major alarm and may indicate a need to replace one or more components (e.g. a Cabinet
Fan may be bad, or check to see if the equipment room air conditioning supply/unit is
functional).
Table 263:
CMC1: Cabinet sensors error log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0Any AnyAnytest environment
1(b
)
257 (c
)
513 (d
)
769 (e
)
1025 (f
)
1281 (g
)
1537 (h
)
1793 (i
)
Any Cabinet
Temperature or
Voltage Query
Test (#122)
MAJ ON test environment