IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005 1403
If the status is bad, the DSPs are taken out-of-service. A reset of the Aggregator hardware is
attempted, and if this is successful the DSPs are placed pack into service.
Packet Count Query #1630
This test is nondestructive.
This test sends a request for a count of packets received by the firmware from the LAN bus on
the TN2602AP IP Media Resource. This test is based on the Medpro DSP looparound test. The
Packet Count Query requests the packet count value from the IP Media Resource, runs the
looparound test on an available port, then requests a second packet count value from the IP
Media Resource. If the second value is greater than the first, then the packet bus is working. If
the second value is not greater than the first, then there is a problem with the packet bus.
Table 496: Test #1629 Aggregator Hardware Query
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Response was not received within the allowable time
2012 ABRT System call failed
2100 ABRT Could not allocate the necessary system resources to run this test
2500 ABRT Internal system error
1 FAIL Reset- not initialized
2 FAIL Heartbeat failure
5 FAIL Aggregator stuck in reset
6 FAIL Aggregator disabled
255 FAIL Internal error
Table 497: Test #1630 Packet Count Query
Error
Code
Test
Result
Description / Recommendation
1000 ABRT Could not seize port for maintenance
1001 ABRT Connection manager could not seize the port
1002 ABRT No time slots available
1 of 2