UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005 2439
1 to 88 FAIL
(
cont’d)
If the UDS1 connects to a line-side terminating device (for example, a
PRI terminal adapter), do the following:
1. Retry the command at 1-minute intervals up to 5 times.
2. Enter list measurement ds1-log location to read the
error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are
administered using the same signaling mode, framing mode, and
line coding.
4. Investigate the maintenance status of the line-side terminating
device.
5. Contact the vendor of the line-side terminating device to diagnose
the equipment.
6. Check the physical connection of the UDS1 interface circuit pack to
the terminating device, and check the premise distribution system
(or the intra-premise wiring) for physical connection failures.
7. Replace the local UDS1 interface circuit pack and repeat the test.
PASS No Slip alarm is detected on the UDS1 Interface circuit pack.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute add ds1
location to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log
to determine whether the board is hyperactive. If so, the board was
shut down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter
busyout board location.
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 864: Test #144 Slip Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation