MODEM-PT (Modem Pool Port)
Issue 1 June 2005 1695
Modem Pool Audit Test (#99)
This audit updates the Modem Pool conversion resource status contained in the TN758 Pooled
Modem circuit pack’s microprocessor. It does not test the Pooled Modem circuit pack, so there
are no FAIL codes. The audit can only be performed on idle conversion resources. If the
conversion resource is in use, the audit aborts.
Table 625: Test #99 Modem Pool Audit Test
Error
Code
Test
Result
Description / Recommendation
None ABRT The system was not able to allocate every necessary resource to execute
this test. An ABORT simply indicates that the conversion resource was in
use when the audit was performed. No repair action is necessary unless
the conversion resource was known to be idle during the test (amber
in-use LED was off) or was busied out before the test was run. In that
case, a TN758 failure condition may exist and the following procedure
should be used:
1. Busyout both of the TN758 Pooled Modem conversion resources on
the circuit pack containing the failing conversion resource.
2. If the test continues to abort, replace the Pooled Modem circuit pack
and retest.