Communication Manager Maintenance-Object Repair Procedures
1826 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1373 ABRT Could not establish the link loop around link to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2060 ABRT Packet link’s bus went down during maintenance loop-around test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If there are errors associated with the packet bus, see PKT-BUS
(Packet Bus) on page 1790.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
1. Retry the command.
NO
BOARD
The IPSI circuit pack’s Packet Interface module is assigned but is not
detected as being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If the IPSI circuit pack is not present, insert a TN2312AP IPSI circuit
pack in the assigned slot, and rerun the test.
Table 671: Test #886 Maintenance Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4