DIG-IP-STN (Digital IP Station)
Issue 1 June 2005 917
Notes:
a. Error Type 1 reports the registration status of the endpoint. If Communication Manager
software claims the endpoint is registered and receives keep-alive handshakes from the
endpoint, the test passes. If keep-alive handshaking has failed, the test fails. If the user has
intentionally un-registered from the S8700 media server, the station is now basically an
AWOH station and is no longer being maintained; no tests run for this station.
b. Error Type 18 is logged when the port/station is busied out by maintenance personnel.
Make sure the port/station is released from busy via release port | station (IP
terminal only).
c. Error Type 257 tracks failures of the signaling path PING test. The test attempts to send a
PING packet to the endpoint IP address, as reported during registration. The PING packet
originates with the C-LAN board through which the endpoint is registered. If the PING
response packet is received, the test passes. If the PING response packet times out, the
test fails.
d. This refreshes the lamp state of every lamp on a virtual DCP station. If successful, the
update always passes. It can abort, but it never fails. This update (test number 16) is the
same one used for existing DCP stations.
e. This refreshes the ringer state on a virtual DCP station and queries the virtual station’s
switch-hook state. If successful, the update always passes. It can abort, but it never fails.
This runs a subset of the entire audit update that runs for standard DCP sets.
f. Error Type 513 indicates that the terminal failed to respond to the ID Query request. This
implies that there is something wrong with the terminal or the communication path. (IP
terminal only).
(e
) Digital Terminal Audit
Update (#17)
WRN OFF
513 (f
) Any Station Digital AUDIT test
(#17)
WRN OFF test port | station
1281 (g
) Any Station Digital AUDIT test
(#17)
WRN OFF test port | station
1537 (h
) 40968 WRN OFF test port | station
1793 (i
)None WRNOFF
2305 (j
) Any None
2817 (k
) Station Hyperactivity
Table 312: DIG-IP-STN Digital IP Station Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2