Communication Manager Maintenance-Object Repair Procedures
928 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Circuit Packs:
● 8400x, 302B1 Terminals
● TN754 (4-wire, mu-law)
Note:
Note: Minimum usable vintage for 8410D and 8434D terminals - V11
● TN413 (4-wire, A-law)
● TN754B (4-wire, A-law/mu-law selectable)
● TN2177 (2-wire, 16-port, A-law/mu-law selectable)
● TN2181 (2-wire, 16-port, A-law/mu-law selectable)
● TN2224 (2-wire, 24-port, A-law/mu-law selectable)
● 603A1/D1 Terminals
● TN754 (4-wire, mu-law),
● TN413 (4-wire, A-law)
● TN754B (4-wire, A-law/mu-law selectable)
S8300 / G700
The MM712 Media Module supports 8410D and 8434D terminals (2-wire, 8-port, A-law/mu-law
selectable).
Programmable Terminals
The following parameters are downloaded to programmable terminals.
Table 318: Parameters Downloadable to Programmable Terminals
Parameter Scope Terminal
International Flags (A-law/mu-law,
Display Mode, DLI Voltage level)
System level 84xx, 603x, 302B1
Primary Levels (Transmission & Sidetone) System level 84xx, 603x, 302B1
Adjunct Levels (Transmission & Sidetone) System level 84xx
Handset Expander Option System level 84xx
Administrable Options
(Speakerphone & Mute Button)
Per-terminal 84xx
Administrable Softkeys Per-terminal, System level 8410D, 8434D