TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005 2317
1005 ABRT This test is not valid for this trunk translation. Must be a wink-start or
delay dial trunk and must be outgoing or 2-way for this test to run.
For the TN2140, the trunk must also be continuous-seize-ack or
discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial
trunk, this abort message should be ignored.
1018 ABRT Test disabled via administration.
1. Verify that the Maintenance Tests field on the Trunk Group
screen is n. To enable the test, enter change trunk-group x
where x is the number of the trunk group to be tested, and enter
y in the Maintenance Tests field.
1040 ABRT This test is not performed for trunk ports administered as access
endpoints.
1. Verify this port is an access endpoint by using display port.
2. If the port has been administered as an access endpoint, then
this test should abort.
2000 ABRT Seizure message is not received back within 10 seconds.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a
translation match at both ends.
3. Check the facility.
2100 ABRT Could not allocate the necessary system resources to run the test.
This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
3 FAIL No dial tone detected from the other end. (TN439 circuit packs only.)
1. Retry the command at one minute intervals up to five times.
2. If the test continues to fail, check the far-end PBX to ensure a
translation match at both ends.
3. Check the facility.
Table 832: Test #73,#747 Tie Trunk Seizure Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3