Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 June 2005 369
Loop-Around Test (#161)
This test is designed to check the on-board transmission capabilities of the NPE on the analog
port.
Table 102: Test #161 Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, wait until it is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to
5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1 of 2