Communication Manager Maintenance-Object Repair Procedures
878 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1392 ABRT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either display port (the
display shows that the port is a TTI port) or list config (the display
shows a “t” for the port).
2. If either list config or display port indicates that the port is not
a TTI port, escalate the problem. If both commands indicate that the
port is a TTI port, the abort is correct for the test, and no action is
necessary.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate the problem if the test continues to abort.
2003 ABRT Failed to receive an off-hook from the Data Line.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2004 ABRT Off hook was not received from the data line device.
1. Busyout the digital port being tested on the data line circuit pack. Retry
the command at 1-minute intervals up to 5 times.
2. If the test still aborts, replace the circuit pack.
2005 ABRT The handshake between the Maintenance/Test circuit pack digital port and
the data line port failed.
1. Resolve any M/T-DIG errors.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test still aborts, replace the data line circuit pack.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2312 ABRT Test did not finish, did not receive loop back data.
1. Resolve any M/T-DIG errors.
2. Retry the test, if still aborts, replace the Data Line circuit pack.
Table 300: Test #171 Digital Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation