Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
732 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1187 ABRT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station
via release station.
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, use
release port location to release the circuit pack, and run the
test again. If the error is present for both BRI-BD and BRI-PORT,
use release board location to release the circuit pack, and
run the test again.
Note:
Note: When you release the circuit pack, you release every port
associated with it. Use busyout port location if ports
still need to be busied out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012 ABRT Internal system error.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
PASS The switch has successfully executed the BRI station audits.
Table 247: Test #630 BRI Set Audits (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2