1132 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Station Lamp Updates Test (#16)
This test lights every lamp on the terminal as specified. The lamp updates will run only if the
station is in service. The status of the station is checked and the lamp updates are blocked from
taking place if the station is not in the in-service state. This test does not affect the status of the
Message Waiting lamp.
Table 385: Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 ABRT System technician may have busied out the port.
1. Look for Error Type 18 (port busied out) for this port. If this error type
is present, then release the port (release station extension)
and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3 ABRT Station may be in ready-for-service or out-of-service state.
1. Use status station to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port is
busy with a valid call.
1. Use display port location to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the
service state of the port. If the port is in use, wait until it is idle before
retesting. Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
3. Retry the command at 1-minute intervals up to 5 times.