Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
912 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
61446 FAIL Battery feed test failed. A loop current fault was detected. This is most
probably an incoming CO-line problem. This failure code is only reported
by the TN2139 Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none is detected refer
the problem to the CO.
2. If the CO-line checks out OK, the failure must be on the DID port.
Replace the circuit pack.
61456 FAIL Battery feed test failed. An on-board problem was detected. This port is
out-of-service.
1. Replace the circuit pack or media module.
61472 FAIL Battery feed test failed. A problem with the incoming CO-line was
detected.
1. Check the incoming CO-line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO-line is not at fault, the failure must be on the DID port.
Replace the circuit pack or media module.
PASS Current flow was detected for this port.
1. User-reported troubles on this port should be investigated using other
port tests and by examining connections.
2. Refer problem to the CO.
Table 310: Test #35 Port Diagnostic Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3